必赢437app登录入口-首页欢迎您

CN EN

SCK8 Series Hall-Effect Open Loop Current Sensor

SCK8 Series open loop current sensor develops on the basic of hall effect principle. Galvanic isolation between primary and secondary circuit of the sensor. Measure DC, AC or pulse currents.

Back Download

Technical Data:

Parame

ters(25°C) Model

SCK8-
50A 100A 150A 200A
Nominal Rms Current (Ipn) ±50AT ±100AT ±150AT ±200AT
Measuring Range (Ip) 150AT 300AT 450AT 450AT
Load resistance Rmax ≥10kΩ
Supply Voltage ±4V
Working voltage DC ±15V(±5%)
Accuracy @ Ta=25°C ±1%
Linearity @ Ta=25°C ±1%
Withstand voltage 2.5kVrms/50Hz/min
Offset Voltage < ±30mV
Offset temperature characteristics < ±0.01%/°C < ±0.05%/°C
Thermal drift of Vo < ±2mV/°C < ±0.6mV/°C (If=0)
Hysteresis offset < ±30mV < ±20mV (if=F.S. 0<--->Nominal RMS Current)
Response time < 5uS
Current consumption <±15mA
Operating temperature -40~+80 °C
Storage temperature -40~+85 °C
Window size: 16mm, Dimension(in mm. 1mm=0.0394 inch):


Remark:

1. Size error: ±1mm;
2. Primary aperture: φ16mm;
3. The IP indication direction is the positive direction of the current, OFS is the zero adjustment, and GIN is the output regulation;
4. Lead pin output, spacing 2.54*4;
5. Two φ2mm pins on the bottom for welding positioning;
6. The temperature of the primary conductor shall not exceed 105°C;
7. Incorrect wiring may cause damage to the sensor.



Shenzhen Socan Technologies Co.,Ltd

Top003101-logo1.png

Address:4th Floor, A3 Bld, Xin Jian Xing Industrial Park, Feng Xing Rd, Guangming Street, Guangming New District, Shenzhen, China

Tel:86-0755-33263060

Fax:+86-0755-33263006

E-mail:sales@szsocan.com

Quote

Name:
Phone:
E-mail:
Content: