SCB1R Series Close Loop Hall effect Current Sensor

 Closed-loop (compensated) current sensor based on Hall effect measurement principle.  The isolation voltage between primary and secondary is greater than 3000VAC.  Can measure DC, AC, pulse, and various irregular waveforms under isolated conditions.  Very low temperature drift, zero drift, fast response time, good linearity, accuracy can reach 0.1%.  Dynamic performance (di/dt and response time) is optimal when the busbar is fully filled with primary perforations.

Back

Drawing & Wiring:

Notes:

1. Size error: ±1mm;
2. Primary aperture: φ20mm;
3. Fastening hole: φ4.5mm*2;
4. SCB1R Output Terminal: 282404-1/AMP;  
5. The IP indication direction is the positive direction of the current, and the OFS is the zero adjustment;
6. Incorrect wiring may cause damage to the sensor.