General Data:
Dimensions(mm):
Parameters(25°C)
Model
SCD9-10mA
SCD9-20mA
SCD9-50mA
SCD9-100mA
SCD9-1A
Nominal Rms
Current (Ipn)
±10mA
DC
±20mA
DC
±50mA
DC
±100mA
DC
±1A
DC
Measuring
Range (Ip)
0~±20mA
DC
0~±40mA
DC
0~±50mA
DC
0~±200mA
DC
0~±1.5A
DC
Load resistance Rmax
≥10kΩ
Output Voltage
±5V
Working
voltage
±12V (±5%)
Accuracy @
Ta=25°C
±1%
Linearity @
Ta=25°C
±0.5%
Input Offset
Voltage
<±150mV
Thermal drift
of Vo
< ±3mV/°C
Resolution
10uA
immunity (to
external interference)
< ± 5mV When H=50A DC/m
Instructions
1.DC leakage current sensor adapt non-contact measurement, it is develop on the basis of the principle of zero magnetic flux modulation and magnetic modulation, it can measure small DC current MA level’s isolation in perforation measurement.
2.Zero position output of the sensor output can be adjusted according to user needs.
3.We can customize different current and voltage output according to user's requirements.
Caution: This product is precision measuring device, please handle with care!